RE: PD initialization

From: Vladimir Piotrovskij Date: October 06, 2000 technical Source: cognigencorp.com
From: "Piotrovskij, Vladimir [JanBe]" <VPIOTROV@janbe.jnj.com> Subject: RE: PD initialization Date: Fri, 6 Oct 2000 13:23:17 +0200 Atul, The NONMEM users guide is rather vague as usual. What you have to do is initializing CMT 2 by putting a dummy AMT equal to 1 at time 0. Then you should pass the baseline level of A(2) (which is K0/KE) to $DES via F2: $PK ... F2 = K0/KE Hope this helps. Best regards, Vladimir ---------------------------------------------------------------------- Vladimir Piotrovsky, Ph.D. Janssen Research Foundation Human Pharmacokinetics (ext. 5463) B-2340 Beerse Belgium Email: vpiotrov@janbe.jnj.com
Oct 05, 2000 Atul Bhattaram Venkatesh PD initialization
Oct 06, 2000 Vladimir Piotrovskij RE: PD initialization
Oct 06, 2000 William Bachman RE: PD initialization
Oct 06, 2000 Jogarao Gobburu Re: PD initialization
Oct 06, 2000 Nelamangala Nagaraja RE: PD initialization
Oct 06, 2000 Sam Liao RE: PD initialization
Oct 06, 2000 William Bachman RE: PD initialization
Oct 06, 2000 Sam Liao RE: PD initialization
Oct 09, 2000 Sriram Krishnaswami PD initialization
Oct 09, 2000 Vladimir Piotrovskij RE: PD initialization
Oct 09, 2000 Vladimir Piotrovskij RE: PD initialization
Oct 09, 2000 Alison Boeckmann PD initialization
Oct 09, 2000 Jogarao Gobburu Re: PD initialization
Oct 09, 2000 Sam Liao RE: PD initialization
Oct 09, 2000 Alison Boeckmann PD initialization