Extreme values of CWRESI in NONMEM 7.4.1?
Paolo:
I reviewed my NONMEM 7.4 testing results on CWRESI, and they provide the same
values in NONMEM 7.3 as well as NONMEM 7.4. In case you ran the problem in
parallel, because NONMEM 7.4 now executes the diagnostic evaluation in parallel
as well, I tested under parallel execution conditions, and the CWRESI values
are also the same between NONMEM 7.4 (parallel) and NONMEM 7.3. Incidentally,
as a diagnostic that is expected to be normally distributed when the model is
correct, CWRES is preferred even when INTERACTION is used in the $EST step.
I would be happy to run your problem and see if I can detect something more
subtle that is involved in your case.
Robert J. Bauer, Ph.D.
Senior Director
Pharmacometrics R&D
ICON Early Phase
820 W. Diamond Avenue
Suite 100
Gaithersburg, MD 20878
Office: (215) 616-6428
Mobile: (925) 286-0769
[email protected]<mailto:[email protected]>
http://www.iconplc.com/