Extreme values of CWRESI in NONMEM 7.4.1?

From: Robert Bauer Date: November 16, 2017 technical Source: mail-archive.com
Paolo: I reviewed my NONMEM 7.4 testing results on CWRESI, and they provide the same values in NONMEM 7.3 as well as NONMEM 7.4. In case you ran the problem in parallel, because NONMEM 7.4 now executes the diagnostic evaluation in parallel as well, I tested under parallel execution conditions, and the CWRESI values are also the same between NONMEM 7.4 (parallel) and NONMEM 7.3. Incidentally, as a diagnostic that is expected to be normally distributed when the model is correct, CWRES is preferred even when INTERACTION is used in the $EST step. I would be happy to run your problem and see if I can detect something more subtle that is involved in your case. Robert J. Bauer, Ph.D. Senior Director Pharmacometrics R&D ICON Early Phase 820 W. Diamond Avenue Suite 100 Gaithersburg, MD 20878 Office: (215) 616-6428 Mobile: (925) 286-0769 [email protected]<mailto:[email protected]> http://www.iconplc.com/
Nov 16, 2017 Paolo Denti Extreme values of CWRESI in NONMEM 7.4.1?
Nov 16, 2017 Robert Bauer Extreme values of CWRESI in NONMEM 7.4.1?
Nov 21, 2017 Robert Bauer RE: Extreme values of CWRESI in NONMEM 7.4.1?