RE: ETA on ALAG1

From: Mouksassi Mohamad-Samer Date: December 12, 2008 technical Source: mail-archive.com
Dear Ayyappa, You may find the following link useful it suggests that a mixture model may be helpful to estimate ETAS: Estimating Variability of Infusion Rate or Duration and Lag Time Using Mixture Models J. Ahn, T. Ludden http://www.aapsj.org/abstracts/AM_2007/AAPS2007-000939.PDF Bests, Samer
Quoted reply history
-----Original Message----- From: [email protected] on behalf of [email protected] Sent: Fri 12/12/2008 16:00 To: [email protected] Subject: [NMusers] ETA on ALAG1 Dear All, It is an old topic, but definetely not completely resolved. Can anybody provide tips on estimating variability on ALAG1 in a 2 comp, oral absorption model (I am using NONMEM V). I am getting an error message OBJFUN is negative. I have searched in usernet archive but could not solve the problem. I appreciate your help. Regards, Ayyappa Chaturvedula GlaxoSmithKline 1500 Littleton Road, Parsippany, NJ 07054 Ph:9738892200
Dec 12, 2008 Ayyappa.5.chaturvedula ETA on ALAG1
Dec 12, 2008 Nidal Alhuniti Re: ETA on ALAG1
Dec 12, 2008 Ayyappa . 5 . Chaturvedula ETA on ALAG1
Dec 12, 2008 Nick Holford Re: ETA on ALAG1
Dec 12, 2008 Nidal . Alhuniti Re: ETA on ALAG1
Dec 12, 2008 Mahesh Samtani RE: ETA on ALAG1
Dec 12, 2008 Alan Xiao RE: ETA on ALAG1
Dec 12, 2008 Mouksassi Mohamad-Samer RE: ETA on ALAG1
Dec 13, 2008 Ayyappa . 5 . Chaturvedula Re: ETA on ALAG1
Dec 13, 2008 Jurgen Bulitta Re: ETA on ALAG1