Re: Capturing AUC between observation time intervals

From: Mats Karlsson Date: April 04, 2002 technical Source: cognigencorp.com
From: Mats Karlsson Subject: Re: [NMusers] Capturing AUC between observation time intervals Date: Thu, 04 Apr 2002 06:21:22 +0200 Hi Chuanpu, I think it would work if you used the code where DADT(x)=C gets the cumulative AUC and then "empty" compartment X and the suitable times by turning the CMT off and back on again (using CMT=-x and CMT=x with EVID=2 data items). This doesn't store the old value, but would work for the problem you described. Best regards, Mats -- Mats Karlsson, PhD Professor of Pharmacometrics Div. of Pharmacokinetics and Drug Therapy Dept. of Pharmaceutical Biosciences Faculty of Pharmacy Uppsala University Box 591 SE-751 24 Uppsala Sweden phone +46 18 471 4105 fax +46 18 471 4003 mats.karlsson@farmbio.uu.se
Apr 03, 2002 Chuanpu Hu Capturing AUC between observation time intervals
Apr 03, 2002 Leonid Gibiansky Re: Capturing AUC between observation time intervals
Apr 03, 2002 Sam Liao RE: Capturing AUC between observation time intervals
Apr 03, 2002 Chuanpu Hu RE: Capturing AUC between observation time intervals
Apr 03, 2002 Chuanpu Hu RE: Capturing AUC between observation time intervals
Apr 04, 2002 Sam Liao RE: Capturing AUC between observation time intervals
Apr 04, 2002 Mats Karlsson Re: Capturing AUC between observation time intervals
Apr 04, 2002 Chuanpu Hu RE: Capturing AUC between observation time intervals