RE: rounding issues with PK data

From: Jeroen Elassaiss-Schaap Date: June 10, 2013 technical Source: mail-archive.com
Hi Nele, That is annoying! These things happen but still.... How I would handle it? I probably would make sure to estimate an additive error next to a proportional/exponential one for PK. Chances are that you would need an additive error to start with, but let's assume that in your case the rounding error would dominate. The additive component may be poorly supported by the data, in which case you could fix it to 0.25 on the SD scale (~95% coverage spans 1.5-2.49). It of course deviates from the expected distribution (uniform) but I would suppose the match is good enough; if you really have a lot of samples around the LLOQ you may want to do some simulation-estimation exercises to ensure there is no bias. Mixing it with other data can be simple: just add a flag for the rounded data, and differentiate inclusion/estimation of the additive component with the flag. The dates for sampling time are good enough after the first week from dosing or so. Generally you would like to make the assumption that the error in IDV is negligible compared to the error in DV. The only option that you have if you can't make the assumption I believe is a method described by Jan Freijer to increase robustness: http://www.page-meeting.org/page/page2005/PAGE2005P76.pdf Hope this helps, Jeroen PS: Bill already answered before I could finish this mail, I am sending anyway because of some additional considerations J. Elassaiss-Schaap Senior Principal Scientist Phone: + 31 412 66 9320 MSD | PK, PD and Drug Metabolism | Clinical PK-PD Mail stop KR 4406 | PO Box 20, 5340 BH Oss, NL
Quoted reply history
From: [email protected]<mailto:[email protected]> [mailto:[email protected]] On Behalf Of Kaessner, Nele Sent: Monday, June 10, 2013 8:05 To: [email protected]<mailto:[email protected]> Subject: [NMusers] rounding issues with PK data Dear nmusers, I have PK data from a compound with a very long half-life (weeks). I have two issues with this data and would very much like to hear your opinion on this: · Concentrations were rounded to integers, with LLOQ of 1. This means a concentration value of 2 could span values from 1.5-2.49, and unfortunately there is no way to find out what was originally measured, and I have quite a few measurements around LLOQ. How would you handle this in the coding (also later when mixing with additional data that was not rounded), and how will this rounding influence my parameter estimates? · The sampling times were only documented as dates (except for the day of dosing). With a long half-life compound, do you consider this to be critical? Your opinions would be very welcome. Best regards Nele ______________________________________________________________ Dr. Nele Käßner Principal Scientist Modeling and Simulation Global Pharmacometrics Experimental Medicine Takeda Pharmaceuticals International GmbH Thurgauerstrasse 130 8152 Glattpark-Opfikon (Zürich) Switzerland Visitor address: Alpenstrasse 3 8152 Glattpark-Opfikon (Zürich) Switzerland Phone: (+41) 44 / 55 51 404 Mobile: (+41) 79 / 654 33 99 mailto: [email protected]<mailto:[email protected]> http://www.takeda.com -------------------------------------------------------------------- The content of this email and of any files transmitted may contain confidential, proprietary or legally privileged information and is intended solely for the use of the person/s or entity/ies to whom it is addressed. If you have received this email in error you have no permission whatsoever to use, copy, disclose or forward all or any of its contents. Please immediately notify the sender and thereafter delete this email and any attachments. -------------------------------------------------------------------- Notice: This e-mail message, together with any attachments, contains information of Merck & Co., Inc. (One Merck Drive, Whitehouse Station, New Jersey, USA 08889), and/or its affiliates Direct contact information for affiliates is available at http://www.merck.com/contact/contacts.html) that may be confidential, proprietary copyrighted and/or legally privileged. It is intended solely for the use of the individual or entity named on this message. If you are not the intended recipient, and have received this message in error, please notify us immediately by reply e-mail and then delete it from your system.
Jun 10, 2013 Nele Kaessner rounding issues with PK data
Jun 10, 2013 Bill Denney Re: rounding issues with PK data
Jun 10, 2013 Jeroen Elassaiss-Schaap RE: rounding issues with PK data