RE: a potential bug
Your problem may be resolved by looking at item 4) in
ftp://nonmem.iconplc.com/Public/nonmem720/nm720_bug_list.pdf
Robert J. Bauer, Ph.D.
Vice President, Pharmacometrics, R&D
ICON Development Solutions
7740 Milestone Parkway
Suite 150
Hanover, MD 21076
Tel: (215) 616-6428
Mob: (925) 286-0769
Email: [email protected]<mailto:[email protected]>
Web: http://www.iconplc.com/
Quoted reply history
From: [email protected] [mailto:[email protected]] On
Behalf Of [email protected]
Sent: Tuesday, April 02, 2013 5:39 PM
To: [email protected]
Cc: [email protected]
Subject: [NMusers] a potential bug
Hello NONMEM Users,
A SAEM code runwell until I tried to replace a block omega
matrix with a diagonal omega matrix. The the code crashed with
the following message:
[Window Title] nonmem.exe
[Main Instruction] nonmem.exe has stopped working
[Content] A problem caused the program to stop working
correctly. Please close the program.
[Close the program]
Another similar code where I made similar changes works well. I
tried to change iniial values for the diagonal omega, but it did
not work. Is it possible we have a bug?
Thanks,
Pavel
>