$PK ADVAN6
Dear NMusers
I have an issue with coding my $PK block (in ADVAN6 (8)) for a particular
situation.
How could I code a punctual removal of a certain amount from a depot
compartment between scheduled multiple doses without having recourse to an
additional and punctual clearance?
In other words, I would like to subtract a certain amount (i.e. negative
bolus, this amount would in fact appear as an individual parameter in the
dataset) without working with rates and clearances? Is it possible?
Let me know if you need additional information.
Many thanks in advance.
Best regards.
Robert