RE: restraining eta code

From: Mats Karlsson Date: March 28, 2006 event Source: cognigencorp.com
From: "Mats Karlsson" mats.karlsson@farmbio.uu.se Subject: RE: [NMusers] restraining eta code Date: Tue, 28 Mar 2006 16:09:10 +0200 Nele, I didn't look at the size of your SD. When it is that large I totally agree with Leonid, that CV is not a useful descriptor of variability. Note also that whenever the typical value is close to 0 or 1, the distribution will be very skewed. Finally, a correction, it is the SD(P) that is approximately OMEGA(ETA(4))*THETA(7)*(1-THETA(7)). Best regards, Mats -- Mats Karlsson, PhD Professor of Pharmacometrics Div. of Pharmacokinetics and Drug Therapy Dept. of Pharmaceutical Biosciences Faculty of Pharmacy Uppsala University Box 591 SE-751 24 Uppsala Sweden phone +46 18 471 4105 fax +46 18 471 4003 mats.karlsson@farmbio.uu.se _______________________________________________________
Mar 28, 2006 Nele Mueller-Plock restraining eta code
Mar 28, 2006 Leonid Gibiansky Re: restraining eta code
Mar 28, 2006 Nele Mueller-Plock Re: restraining eta code
Mar 28, 2006 Mats Karlsson RE: restraining eta code
Mar 28, 2006 Leonid Gibiansky Re: restraining eta code
Mar 28, 2006 Mats Karlsson RE: restraining eta code