RE: calculation of time-to-nadir
From: Nick Holford
Subject: RE:[NMusers] calculation of time-to-nadir
Date: Thu, July 29, 2004 11:31 pm
Anthe,
You are not clear about the context in which you want to calculate the
'time-to-nadir'.
If you want to calculate the time of the minimum prediction based on a NONMEM model
and parameters then you can just follow the advice that Lewis gave previously 'just
simulate your model on a fine time grid and "read off" the value.'.
However, if you are trying to use NONMEM to estimate the 'time-to-nadir' as a model
parameter then this may only be possible for very simple cases (as Lewis pointed out
for Cmax).
If you could give us some idea of why you are trying to do this then perhaps some
suggestions could be made.
Nick
--
Nick Holford, Dept Pharmacology & Clinical Pharmacology
University of Auckland, 85 Park Rd, Private Bag 92019, Auckland, New Zealand
email:n.holford@auckland.ac.nz tel:+64(9)373-7599x86730 fax:373-7556