From: LSheiner Subject: Re: [NMusers] Significance? Date: Wed, 03 Apr 2002 11:23:18 -0800 Quite the contrary. In my experience, the obj function is far more sensitive to differences in goodness of fit than the graphics. I will often find a marginal increment in goodness of fit (say <=10 points) with some modeling change, but be unable to find any picture that looks "better." I do not accept such changes. In contrast, I cannot recall any case in which I could see a clear signal in a picture, which I could not then confirm by making the indicated model change and finding that the obj function changed markedly -- Except where I had made some kind of modeling or coding error! I would definitely not let siuch a thing pass without a very thorough investigation. LBS -- _/ _/ _/_/ _/_/_/ _/_/_/ Professor Lewis B Sheiner, MD _/ _/ _/ _/_ _/_/ mail: Box 0626, UCSF, SF, CA,94143 _/ _/ _/ _/ _/ courier: Rm C255, UCSF, SF, CA,94122 _/_/ _/_/ _/_/_/ _/ 415-476-1965 (v), 415-476-2796 (fax)
Apr 02, 2002 Chyihung Hsu Significance?
Apr 02, 2002 Lewis B. Sheiner Re: Significance?
Apr 03, 2002 Vladimir Piotrovskij RE: Significance?
Apr 03, 2002 Lewis B. Sheiner Re: Significance?
Apr 04, 2002 Vladimir Piotrovskij RE: Significance?
Apr 04, 2002 William Bachman RE: Significance?
Apr 05, 2002 Vladimir Piotrovskij RE: Significance?
Apr 08, 2002 William Bachman RE: Significance?
Apr 15, 2002 Bing Wang RE: Significance?