From: Ekaterina Gibiansky Date: July 13, 2001 technical Source: cognigencorp.com
From: "Gibiansky, Ekaterina" <gibianskye@globomax.com> Subject: RE: Akaike information criterion Date: Fri, 13 Jul 2001 10:58:21 -0400 I used SBC for model selection in NONMEM, and actually compared it with AIC, not in the simulation studies though, but with actual data. With large data sets AIC tends to choose overestimated models, keeping many more covariates, than SBC. SBC seemed to perform well. Katya Ekaterina Gibiansky, PhD Senior Scientist GloboMax LLC 7250 Parkway Drive, Suite 430 Hanover, MD 21076 Voice (410) 782-2234 FAX (410) 712-0737 E-mail: gibianskye@globomax.com
Jul 12, 2001 James Bailey Akaike information criterion
Jul 13, 2001 Mark Sale RE: Akaike information criterion
Jul 13, 2001 William Bachman RE: Akaike information criterion
Jul 13, 2001 Cng Re: RE: Akaike information criterion
Jul 13, 2001 William Bachman RE: RE: Akaike information criterion
Jul 13, 2001 Ekaterina Gibiansky RE: Akaike information criterion
Jul 16, 2001 Ekaterina Gibiansky RE: Akaike information criterion