Error from NUTS estimation
Dear Colleagues
I'm getting an error from NONMEM (7.5.1) when I try to run estimation using
NUTS with multiple problems, with a really trivial model (one compartment, 1
and 2 parameters estimated for the two problems)
The error is:
At line 83 of file
Fortran runtime error: Attempting to allocate already allocated variable
'nuts_iparts3'
Runs fine with single problem and with 2 problems, runs fine with METH=COND,
METH=BAYES or METH=IMPMAP
Seems to crash starting problem #2
The control file is below. Running Window 11, Gfortran
Also, if I'm FIXing a parameter (THETA(2) in problem 1), does it make sense to
have a prior variance? NMTRAN doesn't complain, and it gives reasonable results.
$PROB BASE
$INPUT AMT EVID OBNUM ID TIME DV COV1
$DATA Model_dev1.csv IGNORE=@
$SUBS ADVAN1
$ABBR DERIV2=NO
$PK
V = 1
BASECL = THETA(1)
CLFCOV = THETA(2)
MU_1 = BASECL*(COV1/100)**CLFCOV
CL=DEXP(MU_1+ETA(1))
K = CL/V
$ERROR
IPRED = F
IOBS = IPRED *EXP(ERR(1))
Y=IOBS
$THETA
(-0.356) ; THETA(1) CLEARANCE
(0 FIX) ; THETA(2) CLEARANCE~COV1
$THETAP
(-0.356, FIX)
(0, FIX)
$THETAPV BLOCK(2) FIX VALUES(2,0)
$OMEGA
(0.1) ;; ETA(1) CL
$OMEGAP ;; OMEGA PRIOR
(0.135 FIX)
$OMEGAPD ;; OMEGA PRIOR DF
(5 FIX)
$SIGMA
(0.05) ;; EPS(1)
$SIGMAP ;; SIGMA PRIOR
(0.24 FIX)
$SIGMAPD FIX ;; SIGMA PRIOR DF
5 FIX
$EST METH=NUTS INTER CTYPE=0
$PROB FULL
$INPUT AMT EVID OBNUM ID TIME DV COV1
$DATA Model_dev1.csv IGNORE=@ REWIND
$THETA
(-0.356) ; THETA(1) CLEARANCE
(-0.2877) ; THETA(2) CLEARANCE~COV1
$THETAP
(-0.356, FIX)
(-0.2877, FIX)
$THETAPV BLOCK(2) FIX VALUES(2,0)
$OMEGA
(0.1) ;; ETA(1) CL
$OMEGAP ;; OMEGA PRIOR
(0.135 FIX)
$OMEGAPD ;; OMEGA PRIOR DF
(5 FIX)
$SIGMA
(0.05) ;; EPS(1)
$SIGMAP ;; SIGMA PRIOR
(0.24 FIX)
$SIGMAPD FIX ;; SIGMA PRIOR DF
5 FIX
$EST METH=NUTS INTER CTYPE=0
An ideas?
Thanks
Mark Sale M.D.
Vice President
Integrated Drug Development
[email protected]
Remote-Forestville CA
Office Hours 9 AM - 5 PM Eastern Time
+1 302-516-1684
www.certara.com
[Certara Logo]
This message (including any attachments) may contain confidential, proprietary,
privileged and/or private information. The information is intended to be for
the use of the individual or entity designated above. If you are not the
intended recipient of this message, please notify the sender immediately, and
delete the message and any attachments. Any disclosure, reproduction,
distribution or other use of this message or any attachments by an individual