RE: data

From: Nick Holford Date: September 05, 2022 technical Source: mail-archive.com
Hi, You have non-zero AMT and DV values on the same records. Simple solution is to separate dosing records from observation records. W TIME CP MDV CTIME DAY AMT EVID DV 1 0 0 1 0 1 0.001 1 . 1 0 0 0 0 1 . 0 0.153846 Best wishes, Nick -- Nick Holford, Professor Emeritus Clinical Pharmacology, MBChB, FRACP mobile:NZ+64(21)46 23 53 ; FR+33(6)62 32 46 72 email: [email protected]<mailto:[email protected]> web: http://holford.fmhs.auckland.ac.nz/
Quoted reply history
From: [email protected] <[email protected]> On Behalf Of [email protected] Sent: Monday, 5 September 2022 4:41 PM To: [email protected] Subject: [NMusers] data All: I have data which looks like this with the line number inserted in ( ). WSUBJ TIME CP MDV CTIME DAY AMT EVID DV (1)1 0 0 0 0 1 0.001 1 0.153846 (12)2 0 0 0 0 1 0.001 1 -0.30769 (21)3 0 0 0 0 1 0.001 1 1.076923 I get the following warning with each run. (DATA WARNING 5) RECORD 1, DATA ITEM 9, CONTENTS 0.1538 THE DV DATA ITEM IS POSITIVE, BUT THE MDV ITEM IS 1 (DATA WARNING 5) RECORD 21, DATA ITEM 9, CONTENTS 1.0769 THE DV DATA ITEM IS POSITIVE, BUT THE MDV ITEM IS 1 Each is a dosing for PD; however, it does not happen for record 12, also a dosing record. Can someone tell me why, and how to address this issue?
Sep 05, 2022 Andre Jackson data
Sep 05, 2022 Wdenney RE: data
Sep 05, 2022 Nick Holford RE: data
Sep 05, 2022 Jakob Ribbing Re: data
Sep 14, 2022 Philip Harder Delff Re: data