Re: 2 cmax after a single SC dose
Is this a simulation run? May be residual error? I never seen integration
problem to result in incorrect profiles. Also check the data file, may be extra
dose was given?
Leonid
Quoted reply history
> On Nov 2, 2013, at 8:01 PM, [email protected] wrote:
>
> Hello NONMEM Users,
>
> NONMEM outputs for few subjects look strange. Some subjects have 2 Cmax
> (IPRED) after a single SC dose. One Cmax looks normal. Another one is a
> smaller bump before the normal Cmax. Otherwise, the problem runs OK. Can it
> be an integration error? I use ADVAN13.
>
> Thank you,
> Pavel