RE: how to include inconsistent infusion rate into the model
Hi Tomi,
I haven't done infusion rates that vary with individual. However, you can
model this with between subject variability described on your infusion rates.
If you know what the rate should be, then you can fix that and allow each
individual to vary.
Matt.
>From the NONMEM help
| |
| RATE DATA ITEM |
|_________________________________________________________________|
MEANING: Dose Rate (RATE) data item for PREDPP
CONTEXT: $INPUT record and NONMEM data set
USAGE:
$INPUT ... RATE ...
DISCUSSION:
RATE labels PREDPP's dose rate (RATE) data item. The dose rate data
item is optional. In a dose or reset-dose event record it can take
four kinds of values.
0 The dose is an instantaneous bolus dose.
>0 The dose is an infusion, and the value of RATE gives its rate.
If this is not a steady-state infusion, the AMT data item must be
positive also. If this is a steady-state dose event record, both
AMT and RATE may be 0; (See ss dose).
-1 The dose is a zero-order bolus dose, i.e., an infusion, whose
rate is modeled in the PK routine. As an example, suppose the
compartment being dosed is numbered 1 (e.g., the CMT data item
contains 1, or it contains 0 and compartment 1 is the default
compartment for doses). The $PK abbreviated code must define a
value for R1, the rate parameter for compartment 1, e.g.,
R1=THETA(4)+ETA(4)
-2 The dose is a zero-order bolus dose, i.e., an infusion, whose
duration is modeled in the PK routine. As an example, suppose
the compartment being dosed is numbered 1 as above. The $PK
abbreviated code must define a value for D1, the duration parame-
ter for compartment 1, e.g., D1=THETA(4)+ETA(4)
RATE must be 0 for observation, other-type, and reset event records.
Quoted reply history
-----Original Message-----
From: [email protected] [mailto:[email protected]] On
Behalf Of Tomi Hendrayana
Sent: Friday, August 12, 2011 8:46 AM
To: [email protected]
Subject: [NMusers] how to include inconsistent infusion rate into the model
Dear all,
I ask to the experts here concerning my problem. I am
beginner in using NONMEM and want to include an
inconsistent infusion rate into the model. I collected
sample from cancer patient. Baxter infusion pumps were
used for 24 - 48 hour continuous venous infusion. I
observed that the plasma concentrations varied especially
at the end of infusion, probably due to inconsistent
infusion rate.
Could someone share his experiences with me? Any
suggested code for it will be great help. All responses
will be highly appreciated, thanks in advance and have a
nice weekend ;-)
regards,
-Tomi Hendrayana
Klinische Pharmazie
Pharmazeutisches Institut
Universitaet Bonn
an der Immenburg 4
D-53121 Bonn
This e-mail (including any attachments) is confidential and may be legally
privileged. If you are not an intended recipient or an authorized
representative of an intended recipient, you are prohibited from using, copying
or distributing the information in this e-mail or its attachments. If you have
received this e-mail in error, please notify the sender immediately by return
e-mail and delete all copies of this message and any attachments.
Thank you.