Re: Non-constant parameter

From: Jenny Date: December 23, 1998 technical Source: cognigencorp.com
From: Jenny <zheng.22@osu.edu> Subject: Re: Non-constant parameter Date: Wed, 23 Dec 1998 11:28:47 -0800 Probably my question was not clear. The bladder in my project is depot instead of output compartment, where urine volume changes with time due to urine production. Therefore, another parameter "urine production rate" is involve in the calculation of urine volume. ABoeckmann wrote: > Jenny Zheng asks: > > Does anyone knows how to deal with non-constant parameters(e.g., urine > volume), where parameters are changing with time? > > See Guide V, Introductory, Ch. 6 section 9 (p. 63) for a discussion > of urine volumes.
Dec 22, 1998 Jenny Non-constant parameter
Dec 22, 1998 Alison Boeckmann Re: Non-constant parameter
Dec 23, 1998 Jenny Re: Non-constant parameter