ADVAN9: error in LSODI1: CODE 205
From: "Banken, Ludger {PDBS~Basel}" <LUDGER.BANKEN@Roche.COM>
Subject: ADVAN9: error in LSODI1: CODE 205
Date: Mon, 12 Oct 1998 16:58:29 +0200
Dear NONMEM users,
using ADVAN9, in one problem NONMEM V stops after a few iterations with the following error message:
PRED EXIT CODE = 1
INDIVIDUAL NO. 37 ID=0.20101000E+05 (WITHIN-INDIVIDUAL) DATA REC
NO. 24
THETA=
1.94E-02 8.66E-02 1.70E+01 2.44E+01 1.94E+00 1.90E-01
9.72E+01 7.58E-02 2.43E-01 9.14E-02 4.97E-02
ERROR IN LSODI1: CODE 205
PROGRAM TERMINATED BY OBJ
MESSAGE ISSUED FROM ESTIMATION STEP
Does anybody know the meaning of this error message and how to circumvent it?
Best regards,
Ludger
Biometrics (PDBS, 74/4.OG W)
Pharma Development
F. Hoffmann La Roche Ltd
Grenzacherstrasse 124
CH-4070 Basel, Switzerland
Phone: ++41 61 68 87363; Fax: ++41 61 68 85335; E-mail:
Ludger.Banken@roche.com